Specifications
CODE | 19615 | SIZE | 1500mm, 125mm nozzle |
---|---|---|---|
INLET POSITION | Bottom | INLET SIZE | 2 x 32mm FBSP |
MIN. FLOW AT INLET (L/HR) FOR SHEER DESCENT EFFECT | 6750 | MIN. FLOW AT INLET (L/HR) FOR PROJECTING EFFECT | 13500 |
These pressurised waterfall units are available in the following standard sizes. The 125mm nozzle versions are designed to fit in the mortarline of bricks or blockwork. Always test unit before completely bricking in to ensure it is level and water is falling correctly. The projection maybe adjusted with flow supplied, approx. figures are given below. Note: Customised specifications are NOT available on acrylic waterfalls.
CODE | 19615 | SIZE | 1500mm, 125mm nozzle |
---|---|---|---|
INLET POSITION | Bottom | INLET SIZE | 2 x 32mm FBSP |
MIN. FLOW AT INLET (L/HR) FOR SHEER DESCENT EFFECT | 6750 | MIN. FLOW AT INLET (L/HR) FOR PROJECTING EFFECT | 13500 |
Ensure front outlet is perfectly level. The recommended installation height is 800 to 1000mm from the water surface. Seal around the outlet to prevent possibilty of any leakage back into the wall.
Fit valves to each inlet and ensure tubing length is identical to all inlets.
Install your pump. Ensure its correctly sixed!
Pump prefilter on in-line strainer must be installed to prevent leaf particles etc. from entering the waterfall.
A steel lintel must be installed for any wall or load-bearing structure built above the waterfall.